Product Texts
Vydyne AVS1AF1 NT0840 is a 50% glass fiber reinforced, heat-stabilized PA66 designed for injection molding applications. AVS1AF1 NT0840 offers improved flow with a natural color and maintains the excellent resistance typical of PA66 in chemicals, machine and motor oils, solvents, and gasoline. Application targets include automotive mounts, brackets and suspension components.
Vydyne AVS1AF1 NT0840 has been characterized in anisotropic tensile tests as well as anisotropic fatigue. Material data and models are available at Ascend Performance Materials and in Digimat®-MX.
General
Additive
Heat Stabilizer, Lubricant
Features
General Purpose, Good Flow, Good Heat Resistance, Good Processability, Good Stiffness, High Strength, High Tensile Strength, Lubricated
Automotive Specifications
Tesla TM-1006 v3 - 201150
UL File Number
E70062
Appearance
Natural Color
Forms
Pellets
Processing Method
Injection Molding
Physical
dry
cond.
Unit
Test Norm
Density
1.60
-
g/cm³
ISO 1183
Molding Shrinkage
ISO 294-4
Across Flow : 23°C, 2.00 mm
0.8
*
%
Flow : 23°C, 2.00 mm
0.3
*
%
Water Absorption, 23°C, 24 hr
1.16
*
%
ISO 62
Mechanical
dry
cond.
Unit
Test Norm
Tensile Modulus (23°C)
2.55E6
2.07E6
psi
ISO 527-2
Tensile Stress (Break, 23°C)
36800
29700
psi
ISO 527-2
Tensile Strain (Break, 23°C)
2.3
3
%
ISO 527-2
Flexural Modulus (23°C)
2.39E6
1.77E6
psi
ISO 178
Flexural Strength (23°C)
55100
37900
psi
ISO 178
Poisson's Ratio (23°C)
0.36
ISO 527-2
Impact
dry
cond.
Unit
Test Norm
Charpy Notched Impact Strength
ISO 179/1eA
+23°C
7.61
9.04
ftlb/in²
-30°C
7.61
7.61
ftlb/in²
-40°C
7.61
7.61
ftlb/in²
Charpy Unnotched Impact Strength
ISO 179/1eU
+23°C
47.6
52.8
ftlb/in²
-30°C
47.6
48.5
ftlb/in²
-40°C
46.6
49.9
ftlb/in²
Notched Izod Impact Strength
ISO 180/1A
+23°C
7.14
8.09
ftlb/in²
-30°C
7.61
7.61
ftlb/in²
-40°C
7.61
7.14
ftlb/in²
Thermal
dry
cond.
Unit
Test Norm
Heat Deflection Temperature
ISO 75-2/A
1.80 MPa, Unannealed
486
482
°F
0.45 MPa, Unannealed
502
498
°F
Melting Temperature
500
*
°F
ISO 11357-3
CLTE
ISO 11359-2
Flow : 23 to 55°C, 2.00 mm
13
*
E-6/K
Transverse : 23 to 55°C, 2.00 mm
63
*
E-6/K
Electrical
dry
cond.
Unit
Test Norm
Dielectric Strength (1.00 mm)
889
610
kV/in
IEC 60243