Starflam 525H NT0767 is a heat stabilized, non-halogenated, and non-red phosphorus flame retardant PA66 grade modified with 25% glass fiber for improved stiffness and strength.
General
Additive
Flame Retarding Agent, Heat Stabilizer, Lubricant
Features
Corrosion Resistant, Fast Molding Cycle, Flame Retardant, Good Colorability, Good Dimensional Stability, Good Electrical Properties, Good Processability, Good Tensile Strength, Halogen Content, None, Heat Aging Resistant, Heat Stabilized, High Flow, Low Density, Lubricated
Uses
Flame Retardant, Glass Reinforced
Appearance
Natural Color
Forms
Pellets
Processing Method
Injection Molding
Physical
dry
cond.
Unit
Test Norm
Density
1.40
-
g/cm³
ISO 1183
Molding Shrinkage
ISO 294-4
Across Flow : 23°C, 2.00 mm
1.1
*
%
Flow : 23°C, 2.00 mm
0.3
*
%
Water Absorption
ISO 62
23°C, 24 hr
1.3
*
%
Equilibrium, 23°C, 50% RH
1.9
*
%
Mechanical
dry
cond.
Unit
Test Norm
Tensile Modulus (23°C)
1.33E6
1.06E6
psi
ISO 527-2
Tensile Stress (Break, 23°C)
19700
14100
psi
ISO 527-2
Tensile Strain (Break, 23°C)
3.2
3.4
%
ISO 527-2
Flexural Modulus (23°C)
1.31E6
885000
psi
ISO 178
Flexural Strength (23°C)
30500
18900
psi
ISO 178
Poisson's Ratio (23°C)
0.34
ISO 527-2
Impact
dry
cond.
Unit
Test Norm
Charpy Notched Impact Strength
ISO 179/1eA
+23°C
5.23
6.18
ftlb/in²
-30°C
4.52
4.57
ftlb/in²
-40°C
4.42
4.57
ftlb/in²
Charpy Unnotched Impact Strength
ISO 179/1eU
+23°C
31.9
34.7
ftlb/in²
-30°C
32.3
31.9
ftlb/in²
-40°C
31.9
31.4
ftlb/in²
Notched Izod Impact Strength
ISO 180/1A
+23°C
4.66
5.71
ftlb/in²
-30°C
4.23
4.42
ftlb/in²
-40°C
4.28
4.28
ftlb/in²
Thermal
dry
cond.
Unit
Test Norm
Heat Deflection Temperature
ISO 75-2/A
1.80 MPa, Unannealed
457
442
°F
0.45 MPa, Unannealed
495
489
°F
Melting Temperature
500
*
°F
ISO 11357-3
CLTE
ISO 11359-2
Flow : 23 to 55°C, 2.00 mm
19
*
E-6/K
Transverse : 23 to 55°C, 2.00 mm
68
*
E-6/K
RTI Elec
UL 746
0.200 mm
284
°F
0.400 mm
302
°F
0.750 mm
302
°F
1.50 mm
302
°F
3.00 mm
302
°F
RTI Imp
UL 746
0.200 mm
230
°F
0.400 mm
239
°F
0.750 mm
266
°F
1.50mm
284
°F
3.00 mm
284
°F
RTI Str
UL 746
0.200 mm
248
°F
0.400 mm
257
°F
0.750 mm
284
°F
1.50 mm
302
°F
3.00 mm
302
°F
Electrical
dry
cond.
Unit
Test Norm
Volume Resistivity (1.00 mm)
2.1E13
-
Ohm*m
IEC 60093
Dielectric Strength (1.00 mm)
991
483
kV/in
IEC 60243
Comparative Tracking Index (3.00 mm)
575
V
IEC 60112
High Amp Arc Ignition (HAI)
UL 746
0.400 mm
PLC 0
0.750 mm
PLC 0
1.50 mm
PLC 0
3.00 mm
PLC 0
Hot-wire Ignition (HWI)
UL 746
0.400 mm
PLC 1
0.750 mm
PLC 1
1.50 mm
PLC 0
3.00 mm
PLC 0
Flammability
Value
Unit
Test Norm
Flammability
UL 94
0.200 mm
V-0
0.400 mm
V-0
0.750 mm
V-0
1.50 mm
V-0
3.00 mm
V-0
Flammability, 5V
UL 94
1.50 mm
5VA
3.00 mm
5VA
Glow Wire Flammability Index
IEC 60695-2-12
0.400 mm
1760
°F
0.750 mm
1760
°F
1.50 mm
1760
°F
3.00 mm
1760
°F
Glow Wire Ignition Temperature
IEC 60695-2-13
0.400 mm
1380
°F
Railway Application
dry
cond.
Unit
Test Norm
Oxygen index
34
-
%
EN ISO 4589-2
Smoke Density
134
Ds Max
EN ISO 5659-2
Smoke Toxicity
0.38
CITNLP
NF X 70-100-1/2
Injection
Value
Unit
Drying Temperature
176
°F
Drying Time
4 - 6
h
Rear Temperature
527 - 572
°F
Middle Temperature
527 - 572
°F
Front Temperature
527 - 572
°F
Processing (Melt) Temperature
527 - 572
°F
Mold Temperature
140 - 248
°F